CASE STUDY
MEP/HVAC course project: Office building
- Sum of zone cooling loads
- approx. 89 kW
- Rooms
- 15
- System variants
- 2
- Duct friction rate (equal friction)
- approx. 0.65 Pa/m
Tools · Carrier HAP · AutoCAD · McQuay DuctSizer
01
The project
Online course project: MEP/HVAC design for an office building in Cairo with approx. 700 m² and 15 rooms – from the load calculation through two system variants to the ventilation and system drawings.
- Project type
- Online course project
- Location
- Cairo, Egypt
- Area
- approx. 700 m²
- Rooms
- 15
- Software
- Carrier HAP, AutoCAD, McQuay DuctSizer
- Course / provider
- [to be added]
- Year
- [add year]
FIG. 01.01 — Office building floor plan
- Building
- Office building, Cairo
- Area
- approx. 700 m²
- Rooms
- 15
- Software
- AutoCAD
02
Understanding the demand
Calculated cooling and heating loads for 15 rooms with Carrier HAP.
Measured areas, façades, windows and occupancy for each room from the floor plan myself. Reference values (including lighting) from the ASHRAE Handbook Fundamentals.
approx. 89 kW
Sum of zone cooling loads · Carrier HAP
FIG. 02.01 — Room inputs in Carrier HAP
- Software
- Carrier HAP
- Inputs
- Area, façade, windows, occupants
- Source
- Own take-off from the floor plan
- Reference values
- ASHRAE Handbook Fundamentals
FIG. 02.02 — Zone cooling loads
- Software
- Carrier HAP
- Total
- approx. 89 kW
- Rooms
- 15
03
Evaluating the variants
Two system variants for the same rooms: split units (wall-mounted and cassette units) and ducted ceiling units. Units selected per room according to load and placed in the floor plan.
VARIANT A
Split units (wall-mounted and cassette units)
FIG. 03.01 — Unit placement, variant A
- Software
- AutoCAD
- Selection
- per room according to load
- Unit types
- Wall-mounted and cassette units
- Selection
- per room according to load
- Number of indoor units
- [to be added]
- Air distribution
- [to be added]
- Assessment
- [to be added]
VARIANT B
Ducted ceiling units
FIG. 03.02 — Unit placement, variant B
- Software
- AutoCAD
- Selection
- per room according to load
- Unit types
- Ducted ceiling units
- Selection
- per room according to load
- Number of indoor units
- [to be added]
- Air distribution
- Duct network, equal friction (see 04)
- Assessment
- [to be added]
Both variants designed for the same 15 rooms. [Result of the comparison – text to follow]
04
Designing the air distribution
Sized the duct network of the ducted-unit variant with McQuay DuctSizer using the equal friction method.
approx. 0.65 Pa/m
Duct friction rate · equivalent to 0.08 in.WC/100 ft
FIG. 04.01 — Supply air duct network
- Method
- Equal friction
- Software
- AutoCAD, McQuay DuctSizer
- Duct friction rate
- 0.08 in.WC/100 ft
- Metric
- approx. 0.65 Pa/m
FIG. 04.02 — Detail: duct section
- Excerpt from
- FIG. 04.01
- Area
- [to be added]
FIG. 04.03 — Sizing in McQuay DuctSizer
- Software
- McQuay DuctSizer
- Method
- Equal friction
05
Outdoor air and outlets
Defined supply and exhaust air outlets per room by number, size and air flow rate; outdoor air rates per room taken into account.
FIG. 05.01 — Supply and exhaust air outlets
- Content
- Supply and exhaust air outlets per room
- Defined by
- Number, size, air flow rate
- Taken into account
- Outdoor air rates per room
- Software
- AutoCAD
| Room | Supply air outlets Number · size | Exhaust air outlets Number · size | Supply air flow rate | Outdoor air flow rate |
|---|---|---|---|---|
| [Take values per room from the design – 15 rooms] | ||||
06
Technical results
Ventilation and system drawings in AutoCAD (2D).
- Sum of zone cooling loads
- approx. 89 kW
- Rooms
- 15
- System variants
- 2
- Duct friction rate
- approx. 0.65 Pa/m (equal friction)
- Drawings
- Ventilation and system drawings, AutoCAD (2D)
FIG. 06.01 — Ventilation drawing
- Software
- AutoCAD (2D)
- Drawing type
- Ventilation drawing
- Scale
- [to be added]
FIG. 06.02 — System drawing
- Software
- AutoCAD (2D)
- Drawing type
- System drawing
- Scale
- [to be added]
07
What I learned
[What I learned – text to follow from the owner]